Storage:
Warmly recommended: the Normatherm® buffer storages

- Energy-efficient
- Less emissions
- More heating comfort
- Maximum annual use efficiency
The ideal companion to the Normatherm® water-bearing boiler: the buffer storage. It offers a heating comfort that equals conventional solutions (like fuel oil or gas burners). You do not have to keep the boiler fed with wood and in operation thanks to an adequately dimensioned buffer storage unit.
We recommend a storage of 50 70 litres per kW capacity (500 3000 litres total). The buffer`s dimension should be sufficient to heat up only every second day during transit time.
Numerous buffer storage models are from available Normatherm® - for any application a perfect solution.
buffer storage |
Type |
500 L |
750 L |
1000 L |
1500 L |
dimensions |
|||||
Diameter |
Ø mm |
650 |
750 |
800 |
1000 |
Diameter with isolation |
Ø mm |
850 |
950 |
1000 |
1200 |
Height with isolation |
mm |
1718 |
1800 |
2095 |
2090 |
Pivot / topple measure |
mm |
1755 |
1820 |
2124 |
2144 |
Content |
ltr. |
500 |
750 |
1000 |
1500 |
Surface solar coil (below) |
m² |
1,7 |
2,4 |
3 |
3 |
Content solar coil |
ltr. |
11,3 |
14,9 |
19,5 |
19,5 |
Pressure drop solar coil |
mbar |
8 |
17 |
34 |
34 |
Overpessure storage |
bar |
3 |
3 |
3 |
3 |
Thermal power loss (40 K) |
kWh/24h |
3,3 |
3,3 |
4,6 |
4,6 |
Weight |
kg |
123 |
148 |
170 |
260 |
Measurements for connection |
|||||
SR Solar return |
G1“AG / mm |
218 |
230 |
235 |
310 |
SF Solar flow |
G1“AG / mm |
748 |
800 |
975 |
1048 |
C boiler return 2 |
G11/2“AG / mm |
218 |
230 |
235 |
310 |
D boiler return 1 |
G11/2“AG / mm |
648 |
680 |
745 |
776 |
E boiler return 3 |
G11/2“AG / mm |
1018 |
1030 |
1285 |
1244 |
F boiler return 4 |
G11/2“AG / mm |
1476 |
1480 |
1775 |
1710 |
FC flow circuit |
G11/2“AG / mm |
arranged at the top |
|||
| Multistorage |
Type |
600/150 L |
750/180 L |
1000/200 L |
| Measures |
||||
| Diameter |
Ø mm |
700 |
750 |
800 |
| Diameter with isolation |
Ø mm |
900 |
950 |
1000 |
| Height |
mm |
1860 |
1880 |
2080 |
| Height total (with isolation) |
mm |
1960 |
2020 |
2180 |
| Pivot / topple measure |
mm |
1890 |
1970 |
2125 |
| |
|
|
|
|
| Storage content |
l |
600 |
750 |
1000 |
| Type |
600/150 |
750/150 |
100/200 |
|
| Content water storage |
l |
150 |
180 |
200 |
| Heating water content |
l |
450 |
570 |
800 |
| Surface solar coil |
m² |
0,78 |
0,8 |
1 |
| Continuous output (80/10/45°C / 24 kW) |
l/h |
610 |
610 |
760 |
| Power code |
Ni |
1,9 |
2,4 |
3,1 |
| Necessary flow rate |
m³/h |
2 |
2 |
2,5 |
| Pressure drop (heating) |
mbar |
45 |
45 |
67 |
| Surface solar coil (below) |
m² |
1,7 |
2,3 |
3 |
| Content solar coil |
l |
11,3 |
14,9 |
19,5 |
| Pressure drop solar coil |
mbar |
8 |
17 |
34 |
| Overpessure storage |
bar |
3 |
3 |
3 |
| Overpessure water in use |
bar |
10 |
10 |
10 |
| Thermal power loss (40 K) |
kWh/24h |
3,3 |
3,6 |
4,6 |
| Weight |
kg |
215 |
256 |
305 |
| |
|
|
|
|
| Measurements for connection |
||||
| SR solar return SF solar flow |
G1“AG/mm G1“AG/mm |
200 600 |
220 620 |
220 820 |
| HR heat generator return CR circuit return CF circuit flow HF heat generator flow |
R1“AG / mm R1“AG / mm R1“AG / mm R1“AG / mm |
700 795 1015 1105 |
720 815 1015 1120 |
920 1015 1215 1320 |
Fahw Flow after heating water Rahw Return after heating water |
R1“AG / mm R1“AG / mm |
arranged at the top arranged at the top |
||
warm water connection cold water connection circulation |
R ¾“ AG R ¾“ AG R ½“ AG |
arranged at the top arranged at the top arranged at the top |
||